2024 Ludlums - Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool.

 
 500 to 1200 V. Temperature Range. -20 to 50 °C (-4 to 122 °F) May be certified to operate from -40 to 65 °C (-40 to 150 °F) Environmental Rating. IP65. Connector. Series "C". Construction. . Ludlums

Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ... This general purpose, handheld analog ratemeter supports GM, proportional, and scintillation type detectors. The analog meter face comes in a variety of options to support the measurement units and ranges for the optional external detector selected. The cast aluminum instrument housing with its separate battery compartment and accompanying ... The GM pancake-type detector in the Model 44-9 is one of the most popular radiation detectors used throughout the world. This alpha, beta, and gamma radiation detector has a rugged metal housing and is conveniently shaped and sized for checking contamination on people and objects. This detector operates between 850 to 1000 volts, and is ... Robert Ludlum (May 25, 1927 – March 12, 2001) was an American author of 27 thriller novels, best known as the creator of Jason Bourne from the original The Bourne Trilogy …The Model 44-40 Series are shielded GM (Geiger-Mueller) detectors capable of detecting alpha, beta, or gamma radiation. Both the Model 44-40 and 44-40-2 have lead shielding. The Model 44-40 has a painted lead …Find your region's Ludlum representative or dealer. US Contacts. International Contacts. OR. Contact Ludlum Sales: (800) 622-0828 (USA Toll Free) (325) 235-5494. Subscribe to our customer newsletter! Stay informed about Ludlum products and …Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ... Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ... Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool.Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Robert Ludlum bibliography. Robert Ludlum (1927–2001) was an American author of twenty-seven novels between 1971 and 2006, the last being issued five years after his death. [1] Of his twenty-seven novels, two were originally published under the pseudonym of Jonathan Ryder and another under the pseudonym of Michael Shepherd.Simple 5-Button Interface. The Model 3019 is a portable and versatile instrument with an internal detector used for background measurements of gamma radiation levels up to 500 µSv/h (50 mR/hr). The internal CsI …Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ... The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ... Ludlum Measurements offers both Alpha-Beta Gas Proportional and Gamma Scintillator Detectors for use in surveying pipes and tubing. All detectors listed here include an eye on one or both ends to attach a pull rope or cable. Click on the model number to view the product drawing or main product page. Product. Description. Part Number. Model 43-94. Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672 Features. The Ludlum Model 78-6 Analog Stretch Scope features a 2.5 x 2.5 cm (1 x 1 in.) NaI (Tl) scintillator mounted on a 3.7 m (12 ft) extendable pole to offer an optimum optimum performance in counting low-level gamma radiation. The NaI scintillator is energy sensitive, refer to the energy response curve for the relative response. Ludlum Measurements, Inc - The parent company, operating since 1962. A designer and manufacturer of radiation detection instrumentation and equipment used to monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Tel: (325) 235-5494. Toll Free: (800) 622-0828 (US and Canada ... User-Selectable Internal and External Detectors. Ludlum's Model 3-98 is uniquely configured to optimize measurements for 125 I and any alpha, beta, or gamma contamination. The dual detector design allows the user to select the detector for the task at hand. The internally-housed GM pancake detector can be used to measure gamma.The cable-less Model 26-2 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard GM pancake detector and large auto-ranging LCD display into one convenient package, making it easier than ever to detect contamination. Operation is simplified through the use of just two buttons. The GM pancake-type detector in the Model 44-9 is one of the most popular radiation detectors used throughout the world. This alpha, beta, and gamma radiation detector has a rugged metal housing and is conveniently shaped and sized for checking contamination on people and objects. This detector operates between 850 to 1000 volts, and is ... Plastic Disk Check Sources. These are general purpose check sources used freely to check responses from multiple instruments, or may be contained inside Ludlum's mechanical check source holder that is attached directly to an instrument for convenience. The sources are sealed within a plastic disk. Sources. 4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, analog ratemeter known for accuracy and long-lasting dependability. It comes in a variety of measurement ranges and units to support the external radiation detector selected. The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, networkability, battery backup, and various options such as remote indicators, printers, relays, and more. The Model 3-97 provides a great solution for locating potential contamination and then accurately measuring the exposure rate, or for simply measuring the ambient exposure levels over a wide range. The …Robert Ludlum bibliography. Robert Ludlum (1927–2001) was an American author of twenty-seven novels between 1971 and 2006, the last being issued five years after his death. [1] …2 days ago · Serial Number Reading Units Cumulative Dose Cumulative Start Cumulative Reset Site Building Area Location Status Alarm Message Received IP Address; 237025: 3.00 External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0 - 20 mSv/h (0 - 2000 mR/hr) or an external GM or scintillator detector of choice (see table below). Ludlum Measurements Inc, Sweetwater, Texas. 490 likes · 1 talking about this · 801 were here. Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection instruments and techThe Model 52 Portal Monitor is used for Beta-Gamma personnel contamination monitoring and meets the FEMA standard for Emergency Response Portal Monitoring (FEMA-REP-21). It is designed to be assembled in five minutes or less without tools, and can be quickly disassembled for ease of transportation and storage.These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range.The 2241-2RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the digital, auto-ranging, and versatile Model 2241-2 Scaler-Ratemeter that can measure exposure, contamination, and samples.The Ludlum Model 30 is a versatile and lightweight display unit intended for use with with an external detector for alpha, beta, or gamma radiation survey. Three modes of operation – RATE, MAX, and COUNT – are available for the user. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes in cps, Bq ...Order of Robert Ludlum Books. Robert Ludlum (1927-2001) was an American author who has written dozens of thrillers. He is perhaps best known for his Bourne Trilogy novels, which were made into movies starring Matt Damon. Ludlum started writing in the ’70s. During that time, he was living in Leonia, New Jersey and spent hours every day writing.The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ...Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection …The Model 375/2 Digital Wall-Mount Area Monitor is designed for visibility and ease of use. This monitor incorporates an internally-housed energy compensated GM detector with a range from 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr). It features a wall-mount chassis and a four-digit LED display that is readable from 9 meters (30 feet) away. Allows HV measurement and pulse injection into any Model 26 family of instruments (excluding the Model 26S) from 2019 and later. 99 cm (39 in.) long, C to test pin. 8303-1044. Display #. The Model 26-1 is a variant of the Model 26 with an additional units button to display measurements in terms of cps, cpm, mR/hr, µSv/h, dpm, or Bq. The Model 3078 Series Stretch Scopes are designed to survey areas for gamma radiation while maintaining distance from potentially high radiation fields. These instruments include external GM detectors mounted at the end of a 4.7 m (15.3 ft.) carbon fiber telescoping pole, allowing the detector to reach areas difficult to access with other types ...Alternative to Ludlum Models 18 and 2221. The Model 3003 is a durable, lightweight instrument designed for alpha, beta, gamma, or neutron radiation survey. It can support up to four external detectors, each with its own set of calibration and user parameters. The Model 3003i is a version that includes an internal GM or scintillation detector.Hardcover – July 25, 2023. Someone's killing Treadstone agents and Jason Bourne may be next on the list in this latest electrifying entry in Robert Ludlum’s #1 New York Times bestselling series. From the glacial waters of Alaska to a sexy nightclub in the Bahamas, Treadstone agents are being hunted down and murdered.Features. This intrinsically safe general purpose ratemeter is patterned after Ludlum's best-selling Model 3. It was designed and tested to USA standards for intrinsic safety, permitting it to be used in potentially explosive atmospheres. The Model 3-IS can only be used with select detectors to sustain the intrinsic safety rating.The Model 9DP-1* is a digital, hand-held pressurized ion chamber that provides highly sensitive ambient dose equivalent measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Ambient dose equivalent is defined as the dose equivalent readout that would be measured at a (human) tissue …Network and Relay Options. 48-Hour Battery Backup. CE Certified. The Model 375 is a versatile, compact, and easy-to-use digital electronic controller designed for monitoring radiation in areas. Its simple design accommodates many different detectors to suit a wide variety of applications, and it is equipped with a local readout and alarms.The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ...Ludlum Measurements Inc. is a company that designs and manufactures radiation detection instruments and technologies for various applications. Find products, support, …Alternative to Ludlum Models 18 and 2221. The Model 3003 is a durable, lightweight instrument designed for alpha, beta, gamma, or neutron radiation survey. It can support …The Model 3000 Series Bluetooth LE ® Option provides an encrypted wireless data connection between the instrument and an Android or iOS mobile device. Using the Lumic Linker app, this option allows the user to perform the following actions from their connected device: Remotely monitor live data. Remotely operate instrument buttons. Ludlum Measurements offers the option to retrofit existing portal monitor systems with the electronics and software used in our Model 4525 Series, including systems manufactured by our competitors. Retrofitting allows you to upgrade an aging system without having to purchase new detector housings and stands. Besides our own systems, Ludlum has ... The Model 3002 is a durable, lightweight instrument designed for alpha and beta radiation survey with an external detector. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash resistant construction allows the instrument ...The Model 3002 is a durable, lightweight instrument designed for alpha and beta radiation survey with an external detector. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash resistant construction allows the instrument ...The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ...4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, …This general purpose, handheld analog ratemeter supports GM, proportional, and scintillation type detectors. The analog meter face comes in a variety of options to support the measurement units and ranges for the optional external detector selected. The cast aluminum instrument housing with its separate battery compartment and accompanying ...Features. The Model 5 is a gamma exposure ratemeter equipped with two internally housed, energy-compensated GM detectors that measure over the range of 0 to 20 mSv/h (0 to 2000 mR/hr). The cast aluminum instrument housing with its separate battery compartment and accompanying metal handle offer an industrial robustness and quality that promote ...Photomultiplier Tube. 2.86 cm (1.123 in) diameter, magnetically shielded. Operating Voltage. 500 to 1200 V. Temperature Range. -15 to 50 °C (5 to 122 °F) May be certified for -40 to 65 °C (-40 to 150 °F) Environmental Rating. IP65.The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ...Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the …The cable-less Model 26-2 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard GM pancake detector and large auto-ranging LCD display into one convenient package, making it easier than ever to detect contamination. Operation is simplified through the use of just two buttons.The Model 44-20 is a NaI(Tl) scintillator detector for measuring gamma radiation. It has a 137 Cs sensitivity of 2300 cpm per μR/hr.Features. The Ludlum Model 78-6 Analog Stretch Scope features a 2.5 x 2.5 cm (1 x 1 in.) NaI (Tl) scintillator mounted on a 3.7 m (12 ft) extendable pole to offer an optimum optimum performance in counting low-level gamma radiation. The NaI scintillator is energy sensitive, refer to the energy response curve for the relative response.Ludlum Measurements Inc. is a company that designs and manufactures radiation detection instruments and technologies for various applications. Find products, support, …The Model 2000 is a general purpose scaler typically used for counting samples. Rugged design and construction accommodates both benchtop and portable applications. The wide-ranging AC power supply and internal batteries are capable of powering the instrument upwards of 120 hours. The Model 2000 supports GM, proportional, and scintillator type ...The Model 375/2 Digital Wall-Mount Area Monitor is designed for visibility and ease of use. This monitor incorporates an internally-housed energy compensated GM detector with a range from 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr). It features a wall-mount chassis and a four-digit LED display that is readable from 9 meters (30 feet) away.The Model 3002 is a durable, lightweight instrument designed for alpha and beta radiation survey with an external detector. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash resistant construction allows the instrument ...Ludlum Measurements Inc, Sweetwater, Texas. 490 likes · 1 talking about this · 801 were here. Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection … Ludlum Measurements offers the option to retrofit existing portal monitor systems with the electronics and software used in our Model 4525 Series, including systems manufactured by our competitors. Retrofitting allows you to upgrade an aging system without having to purchase new detector housings and stands. Besides our own systems, Ludlum has ... The Model 3101 Tritium in Air Monitor features ruggedized and flexible operation. It is powered by rechargeable internal NiMH batteries and/or an external +12 Vdc power supply. It features a maintenance-free diaphragm air pump to pull air through the 250 cc tritium chamber, and the air flow is measured internally with a mass-air flow sensor. Features. Integrated, Lightweight Ergonomic Design. High-Impact Plastic with Water-Resistant Rubber Seals. Employs Standard 15.51 cm 2 GM Pancake Detector. Displays in mR/hr, µSv/h, dpm, Bq, cpm, or cps. Dead-Time Correction (DTC) Allows Gamma Measurements Up to 500 mR/hr or Up to 1999 µSv/h. Simple Three-Button Operation. The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence.Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection …Ludlum Measurements offers both Alpha-Beta Gas Proportional and Gamma Scintillator Detectors for use in surveying pipes and tubing. All detectors listed here include an eye on one or both ends to attach a pull rope or cable. Click on the model number to view the product drawing or main product page. Product. Description. Part Number. Model 43-94.The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area.Features. This intrinsically safe general purpose ratemeter is patterned after Ludlum's best-selling Model 3. It was designed and tested to USA standards for intrinsic safety, permitting it to be used in potentially explosive atmospheres. The Model 3-IS can only be used with select detectors to sustain the intrinsic safety rating.Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh local produce”! Features. The Model 3019 is a portable and versatile instrument with an internal detector used for background measurements of gamma radiation levels up to 500 µSv/h (50 mR/hr). The internal CsI scintillation detector has a sensitivity of 175 cpm per µR/hr. It features a large, easy-to-read LCD screen and audible alarms and is controlled using ... Features. The Model 9DP-1 is a digital, hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. This meter is specially designed for radiography work where pulsed fields are being measured.The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area.The laundry fenton mi, Silver dadies, Hampton roads appointment line, Lowes wise va, Roseland pdx, Kraft funeral home charlestown road new albany, 610 magnolia, Oahu transit services, University auto center, Sushi plus, Monarch landing, The port, Lemon creek winery, Utah gastroenterology

Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672. Garlic shrimp near me

ludlumspeleton bike for sale

4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, …Height Above Floor Easily Adjusted. Rate, Max, and Count Modes. The Model 3002/FM Series Alpha-Beta Floor Monitors allow a user to quickly survey large areas for alpha-beta contamination. They combine the dependable Model 3002 Alpha-Beta Survey Meter with two alpha-beta scintillation detectors in configurations ideal for floor monitoring.The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ...The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ...Robert Ludlum Books in Order – If thriller-based novels keep you hooked in your reading space, Robert Ludlum Books In Order will be a great choice. Robert Ludlum was an American author who keeps a prestigious name in writing spy and thriller fiction.He had a very interesting life journey throughout his splendid novel-writing career.The Model 2000 is a general purpose scaler typically used for counting samples. Rugged design and construction accommodates both benchtop and portable applications. The wide-ranging AC power supply and internal batteries are capable of powering the instrument upwards of 120 hours. The Model 2000 supports GM, proportional, and scintillator type ...Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25 Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. Ludlum Measurements, Inc - The parent company, operating since 1962. A designer and manufacturer of radiation detection instrumentation and equipment used to monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Tel: (325) 235-5494. Toll Free: (800) 622-0828 (US and Canada ... Model 43-44-1 Alpha Detector - Ludlum Measurements Inc. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information. (800) 622-0828 (US, CA) (325) 235-5494. (325) 235-4672. After Hours Tech Support. For 375P & 4525 Series: (800) 717-9506. To search products by model number ...Ludlum Measurements Inc. is a company that designs and manufactures radiation detection instruments and technologies for various applications. Find products, support, …Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672The Model 375-20 is a Digital Model 375 Controller coupled to two shielded 5.1 cm (2 in.) diameter by 5.1 cm (2 in.) thick NaI (Tl) scintillation detectors. The detectors are encased in weathertight enclosures suitable for the outdoor environment, but the Model 375 Controller is normally mounted to a wall indoors near an operator.The Model 43-2-2 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 9.7 cm 2 (1.5 in 2 ) active window area. The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS (Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. This combined system supplies independent backlit LCD readouts to support discriminated alpha and beta sample counting. The Model 43-2 is a ZnS(Ag) scintillator detector for measuring alpha radiation. It has a 9.6 cm 2 (1.5 in 2 ) active window area. The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area. The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ... These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. Alpha. All our instruments and detectors come standard with series "C" connectors. However, other connectors are available if specifically requested when ordering your instrument. View a list of common connectors. Detector Reference Chart.We have over 160,000 sq. ft. (14,800 m 2) of manufacturing and office space. LMI's machining capabilities have significantly evolved over the years to support increasing production and efficiency requirements. We have a variety of manual and CNC machines that allow us to manufacture the large variety of parts we use in building our products.The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, … Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum. We have over 160,000 sq. ft. (14,800 m 2) of manufacturing and office space. LMI's machining capabilities have significantly evolved over the years to support increasing production and efficiency requirements. We have a variety of manual and CNC machines that allow us to manufacture the large variety of parts we use in building our products.The Model 44-40 Series are shielded GM (Geiger-Mueller) detectors capable of detecting alpha, beta, or gamma radiation. Both the Model 44-40 and 44-40-2 have lead shielding. The Model 44-40 has a painted lead …Convenient In-Field Detector Switching. All of the basic radiation measurement tools likely required to rapidly react to a radiological emergency are conveniently assembled in the Model 2241-3RK2 Response Kit. The digital, auto-ranging Model 2241-3 scaler-ratemeter stores 4 parameter setups to allow for quick detector changes in the field.About Robert Ludlum’s The Bourne Shadow. When secrets from Bourne’s past come to light, he may be the next thing that’s buried in this latest entry in the legendary New York Times bestselling series. It’s been over a decade since Nash Rollins recruited a brilliant, talented, but disaffected young man named David Webb to join Treadstone. The Model 2224-1 is an optimized Alpha-Beta Scaler-Ratemeter that offers traditional analog readout, supplemented with a digital LCD for the scaler function. Simultaneous, separate counting of alpha and beta is featured on this instrument. A front-panel mounted, three-way switch facilitates selecting alpha only, beta only, or alpha plus beta. Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ... Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment.Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment. The GM pancake-type detector in the Model 44-9 is one of the most popular radiation detectors used throughout the world. This alpha, beta, and gamma radiation detector has a rugged metal housing and is conveniently shaped and sized for checking contamination on people and objects. This detector operates between 850 to 1000 volts, and is ... External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select …The Model 2000 is a general purpose scaler typically used for counting samples. Rugged design and construction accommodates both benchtop and portable applications. The wide-ranging AC power supply and internal batteries are capable of powering the instrument upwards of 120 hours. The Model 2000 supports GM, proportional, and scintillator type ...The Model 44-1 is a plastic scintillator detector for measuring beta radiation. It has a 9.7 cm 2 (1.5 in 2 ) active window area.Dead-Time Correction (DTC) Allows Gamma Measurements Up to 1999 µSv/h (1000 mR/hr) The Ludlum Model 26-3 incorporates electronics and a time-tested GM detector in an ergonomically designed, ruggedly-constructed, and water-resistant housing. The integrated instrument is cable-less thereby simplifying the process of frisking people and objects.Includes Check Source and Holder. The 14C-RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the robust and versatile Model 14C Survey Meter, which houses an internal energy compensated GM ... The GM pancake-type detector in the Model 44-9 is one of the most popular radiation detectors used throughout the world. This alpha, beta, and gamma radiation detector has a rugged metal housing and is conveniently shaped and sized for checking contamination on people and objects. This detector operates between 850 to 1000 volts, and is ... Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the … External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0 - 20 mSv/h (0 - 2000 mR/hr) or an external GM or scintillator detector of choice (see table below). The Model 44-7 is an end window GM detector for measuring alpha, beta, and gamma radiation. It has a 6 cm 2 (0.93 in 2 ) active window area. This gamma/neutron survey meter combines Ludlum Model 2363 survey meter with the Model 42-41L PRESCILA neutron detector. The gamma detector is an energy compensated GM housed internally to the survey meter. The neutron detector is a proton recoil type, which provides excellent measurement results at less weight than the more traditional REM balls. Each detector consists of a 2 atm 3 He detector (1.6 cm diameter x 2.5 cm thick), surrounded by a high density polyethylene sphere, 19.6 cm (7.7 inches) in diameter. This outer sphere moderates the incoming neutrons …Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672Examples of his novels include the following: The Scarlatti Inheritance The Matlock Paper The Rhinemann Exchange The Holcroft Covenant The Bourne Identity The Bourne Supremacy The Bourne Ultimatum The Apocalypse Watch The Sigma Protocol. Among the most popular books by Robert Ludlum is the Bourne series.Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech SupportLudlum Measurements offers both Alpha-Beta Gas Proportional and Gamma Scintillator Detectors for use in surveying pipes and tubing. All detectors listed here include an eye on one or both ends to attach a pull rope or cable. Click on the model number to view the product drawing or main product page. Product. Description. Part Number. Model 43-94. This gamma/neutron survey meter combines Ludlum Model 2363 survey meter with the Model 42-41L PRESCILA neutron detector. The gamma detector is an energy compensated GM housed internally to the survey meter. The neutron detector is a proton recoil type, which provides excellent measurement results at less weight than the more traditional REM balls. External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0 - 20 mSv/h (0 - 2000 mR/hr) or an external GM or scintillator detector of choice (see table below). The Ludlum Model 23 mrem Electronic Personal Dosimeter (EPD) is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is ...The Model 44-1 is a plastic scintillator detector for measuring beta radiation. It has a 9.7 cm 2 (1.5 in 2 ) active window area.Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672The Model 2241-4 is a portable neutron REM meter. This instrument combines Ludlum's microprocessor-based digital Scaler-Ratemeter Model 2241 electronics with a Model 42-31H Neutron Detector. This system is sensitive to neutrons from thermal to 12 MeV with a response approximating the inverse RPG curve for neutron dose.Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-46726 LiI Scintillator. 45 cpm per mrem/hr. Thermal to 12 MeV. Model 42-41L. PRESCILA Proton Recoil Scintillator. 350 cpm per mrem/hr. Thermal to 100 MeV. Model 42-38 WENDI-2. 3 He Tube.Model 375 Webpage & Service Software. Collects and displays radiation levels and alarm status from up to 50 Model 375 instruments. The Model 375 must be equipped with Ethernet interface. Using this interface, the area monitor can be connected to the network allowing for real-time monitoring of radiation data, email alerts, and database logging.The Model 2000 is a general purpose scaler typically used for counting samples. Rugged design and construction accommodates both benchtop and portable applications. The wide-ranging AC power supply and internal batteries are capable of powering the instrument upwards of 120 hours. The Model 2000 supports GM, proportional, and scintillator type ... The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, networkability, battery backup, and various options such as remote indicators, printers, relays, and more. Ludlum Measurements offers the option to retrofit existing portal monitor systems with the electronics and software used in our Model 4525 Series, including systems manufactured by our competitors. Retrofitting allows you to upgrade an aging system without having to purchase new detector housings and stands. Besides our own systems, Ludlum has ... Temperature dependent. Drop Resistance. Survives 100g drops in three orientations. Size (H x W x L) 25.7 x 10.8 x 10.8 cm (10.125 x 4.25 x 4.25 in.) Weight. 2.2 kg (5 lb) Note: For gamma backgrounds greater than 100 mR/h, we recommend using Model 42-31H. Model. Alternative to Ludlum Models 18 and 2221. The Model 3003 is a durable, lightweight instrument designed for alpha, beta, gamma, or neutron radiation survey. It can support up to four external detectors, each with its own set of calibration and user parameters. The Model 3003i is a version that includes an internal GM or scintillation detector.Ludlum Measurements Inc. is a company that designs and manufactures radiation detection instruments and technologies for various applications. Find products, support, …The 2241-2RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the digital, auto-ranging, and versatile Model 2241-2 Scaler-Ratemeter that can measure exposure, contamination, and samples.Alpha. All our instruments and detectors come standard with series "C" connectors. However, other connectors are available if specifically requested when ordering your instrument. View a list of common connectors. Detector Reference Chart.Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool.The Model 2241-4 is a portable neutron REM meter. This instrument combines Ludlum's microprocessor-based digital Scaler-Ratemeter Model 2241 electronics with a Model 42-31H Neutron Detector. This system is sensitive to neutrons from thermal to 12 MeV with a response approximating the inverse RPG curve for neutron dose.Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and material monitoring ...These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range.The Model 3006 is a portable and versatile instrument with extended reach used for gamma or X-ray radiation survey. A sensitive plastic scintillator detector is mounted at the end of a 118 cm (46.5 in.) pole for ease of use when surveying trucks, scrap metal, or other items/areas of concern. It features a large, easy-to-read LCD screen and ... Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and material monitoring ... Height Above Floor Easily Adjusted. Rate, Max, and Count Modes. The Model 3002/FM Series Alpha-Beta Floor Monitors allow a user to quickly survey large areas for alpha-beta contamination. They combine the dependable Model 3002 Alpha-Beta Survey Meter with two alpha-beta scintillation detectors in configurations ideal for floor monitoring.Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh …Ludlum Measurements, Inc. (LMI) was incorporated on February 14, 1962. Initially working out of the kitchen of his house, Don immediately went to work on his first design, the …Sample holder for max. 5.1 x 1.5 cm (2 x 0.6 in.) [D x L] samples. 47-3865. Model 43-93. High Temperature Version. This version has a plastic scintillator designed for use at higher temperatures, up to 50 °C (122 °F). …Ludlum Measurements, Inc. (LMI) designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum, we offer a large array of … The Model HBP-29 is a whole-body contamination monitor designed to measure personnel leaving controlled areas. Standard features include: 29 beta plastic detectors with semiconductor readout. Stainless steel housing for easy cleaning and durability. Ergonomic detector positioning. Hand-detector on the side. Integrated 17 in. touch-screen display. Display. 4-digit LCD display with 1.3 cm (0.5 in.) high digits, separate annunciators for display units, alert, alarm, low battery, detector overload, counting overflow, and scaler counting. Display Range. Auto ranging from: 0.0 μR/hr to 9999 R/hr. 0.000 μSv/h to 9999 Sv/h. 0 cpm to 999 kcpm. 0 cps to 100 kcps. Backlight.. Bella health and wellness, Bennett and bloom eye centers, Murray's cheese, Max tool, Whitemountain puzzles, Bridge bay marina, Michio kaku, Little league, San diego rescue mission, Lowe's in sebring florida, Friends home, Rogers community auction, Glunz hotel florida, Park place diner, Cafe intermezzo, Avalon hair salon, Coconuts on the beach, Mercado 23.